Power Analyzers and Power Meters

Author: Evelyn

Sep. 02, 2024

Measurement & Analysis Instruments

Power Analyzers and Power Meters

±(0.8% rdg + 0.2% rng) when using clamps , , , , ±(1.1% rdg + 0.2% rng) when using clamp , ±(1.3% rdg + 0.2% rng) when using clamp ,

If you want to learn more, please visit our website SUIN.

Peak voltage of 2 kV or RMS of 1.1 kV, whichever is lower

Peak voltage of 1.5 kV or RMS of 1.0 kV, whichever is lower

Peak voltage of 1.5 kV or RMS of 1.0 kV, whichever is lower

Peak voltage of 1.5 kV or RMS of 1.0 kV, whichever is lower

The peak is 1.5 kV, or the RMS of 1kV, whichever is less.

The peak is 1.6 kV, or the RMS of 1.1kV, whichever is less.

Peak voltage of 2 kV or RMS of 1.1 kV, whichever is lower

Peak voltage of 1.6 kV or RMS of 1.5 kV, whichever is lower

Continuous Allowable Max. Input Current

Direct input (5 A element): Peak current of 10 A or RMS of 7 A (whichever is lower.), Direct input (30 A element): Peak current of 90 A or RMS of 33 A (whichever is lower.) External Current Sensor Input - Peak not to exceed 5 times range-value or 25 V (whichever is lower)

Direct input (5 A element): Peak current of 10 A or RMS of 7 A (whichever is lower.), Direct input (50 A element): Peak current of 150 A or RMS of 55 A (whichever is lower.) External Current Sensor Input - Peak not to exceed 5 times range-value

30A direct input: The peak is 90 A, or RMS is 33 A, whichever is less. 2A direct input: The peak is 6 A, or RMS is 2.2 A, whichever is less. Current sensor input: The peak is not to exceed 5 times the range

Direct input: The peak is 100 A, or RMS is 45 A, whichever is less. External input: The peak is 5 times the range or less.

Direct input: 5-200 mA Peak current of 30 A or RMS of 20 A (whichever is less.), 0.5-20 A Peak current of 100 A or RMS of 30 A (whichever is less.) External input: Peak value of 5 times range or less.

Direct input: 1-20 A Peak current of 100 A or RMS of 44 A (whichever is less.) External input: Peak value of 5 times range or less.

Direct input: 0.5-20 A Peak current of 100 A or RMS of 30 A (whichever is less.) External input: Peak value of 5 times range or less.

If you are looking for more details, kindly visit Single-Phase Power Quality Analyzer Agencies.

Direct input: 8.5 A Peak or RMS of 6 A (whichever is less.) External input: Peak value of 4 times range or less.

(2A) 60Arms (50A) 130Arms (100A) 100Arms (200A) 250Arms (500A) 500Arms (A) A (A) A

Power Analyzers | Energy Loggers

Power Analyzers / Energy Loggers

Why AEMC® Instruments Power Analyzers/Energy Loggers?

We know how critical it is for electricians and facility maintenance professional to troubleshoot and benchmark power quality issues over time. Our easy-to-use line of portable power quality analyzers, power and energy loggers, and meters are designed to:

  • Identify power, quality and energy waste in your facility
  • Ensure continuity of service
  • Find intermittent problems with voltage
  • Detect and prevent power issues before they become costly problems
  • Record trend, transient, event and harmonic data simultaneously &#; saves time finding problem areas
  • Assist in capturing accurate power and energy data necessary to maintain optimum performance and reliability
  • Included DataView® software for easy analysis and reporting
  • Real-time display provides on-site analysis capability
  • All key measurement functions are available with one button access &#; eliminating confusion and error
  • All needed probes and accessories included &#; no guess work needed to be sure you have everything you need

Powerful and Flexible Data Analysis Software

Our powerful DataView software is included to provide valuable insights about the performance of your electrical system. The software helps you:

  • Display and analyze real-time data
  • Configure functions and parameters
  • Customize views, templates and reports to your exact needs
  • Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs and stored alarms
  • Lifetime of free updates

Applications of Use

Our instruments support a wide range of applications including:

  • Power and electric monitoring
  • Harmonic detection & analysis
  • Utility testing
  • Energy management
  • Power factor analysis and correction
  • Power demand and consumption
  • kW measurement
  • Industrial power systems
  • Commercial maintenance

Power Analyzer Comparison Chart

We created this all-in-one comparison document to help you select a proper Power Analyzer for your specific needs.

Comparison Chart

Cuadro Comparativo &#; Español

Power Energy Logger (PEL) Comparison Chart

We created this all-in-one comparison document to help you select a proper Power Energy Logger (PEL) for your specific needs.

PEL Comparison Chart

Cuadro Comparativo &#; Español

Expert Tech Support

AEMC® provides complete technical support through our technical hot line 800-945- (ext.351), speak directly to one of our tech support team members today. Or your questions to our tech team.

Excellent Customer Service

Our knowledgeable and friendly service team provides the best support in the industry. We seek to understand your inquiry or feedback in a respectful and responsive way. Our goal at AEMC Instruments is to surpass your expectations.

Speak directly to one of our customer care team members today at 800-945- (Ext. 361). Or your questions

Request a Demo

Have questions on how to use AEMC® Power Analyzers and Energy Loggers? We're happy to provide a demonstration with our technical experts. Contact us at (800) 343- or us at

For more information, please visit Single-Phase Power Quality Analyzer Supplier.

9

0

Comments

Please Join Us to post.

0/2000

All Comments ( 0 )

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name: (required)

Your Email: (required)

Subject:

Your Message: (required)