Does your boiler or central heating keep losing pressure?
gtboiler contains other products and information you need, so please check it out.
Topping up your boiler / central heating system is perfectly normal from time to time and could also be required if:
However, if you find that you need to top up your boiler pressure weekly, daily or even hourly then there is a problem that needs to be fixed.
Read on as we explore some of the reasons why your boiler could be losing pressure and what to do to resolve them.
What Is Boiler Pressure & How Do I Top It Up?
All Combi boilers, system boilers and boilers on a sealed system are filled through a manually operated filling point somewhere in your central heating system. This may be a filling loop which incorporates 2 valves to allow you to turn on and off connected with a braided hose or some boilers have filling points attached and instructions on how to work these can be found in the manufacturers instructions.
You should always bleed the heating system when the water has cooled and once you have bled the radiators then top up the pressure between 1-1.5 bar of pressure on the display gauge on your boiler or system, the actual pressure you set it at will depend on the number of radiators you have and the amount of pipework on the heating system, a rule of thumb is if you have a smaller system the pressure can be set at 1.5 bar and for a larger system 1.0 bar would be better.
The reason we top up the system when it has cooled is that when the central heating heats up the water expands and causes the pressure to increase, this is normal and no need to worry, but if you have the initial pressure too high it means when the water heats up it will over pressurise and will then discharge through the pressure relief valve to outside and this will drop the system pressure to zero or near zero which you will then have to top up the pressure and if you over pressurise it again without being aware of where it should be set you will be caught in a cycle of topping up the water pressure.
Some heating systems that are bigger may require an extra expansion vessel to allow for the extra expansion of water, always seek advice if you think this may be a case.
Frequently topping up the pressure will eventually lose all the inhibitor from the system which can lead to corrosion within the heating system.
Causes of Frequently Dropping Pressure
Sometimes other things can cause the pressure to drop frequently but these causes will need to be dealt with by a qualified heating engineer but here is what to look out for:
Problem: Leaks
You could have a leak inside your boiler or somewhere on your central heating system and this will cause the system pressure to drop.
What You Can Do
Featured content:If you are looking for more details, kindly visit Wall Mounted Condensing Gas Boiler.
Check for any visible wet marks in the house, check radiators and radiator valves for leaks, check ceilings for damp patches and check there is no leaks under the boiler if you can, unfortunately if the leak is under the floor you will not see it.
Problem: Faulty Pressure Relief Valve
This valve is generally within your boiler and when it is faulty it will let water out of the system and cause the pressure to drop.
What You Can Do
The pipework from this valve will go to outside so just trace the pipe that goes outside and see if there is any water dripping or running from it which would indicate a faulty valve.
Problem
: Flat Or Faulty Expansion Vessel
Generally an expansion vessel is fitted within the boiler but can be fitted external to the boiler as well, an expansion vessel is pressurised with air and allows the expansion of the heating water, when the vessel is flat or faulty it wont allow the water to expand which will make the system over pressurise and will discharge outside and drop the pressure to zero or near zero.
What You Can Do
You can monitor the pressure gauge on your boiler or system when it is cold, turn on the central heating and if your gauge rises quicker and higher than normal it suggests your vessel needs to be re-pressurised or replaced.
Need more help?
For any pressure problems or other issues with your heating always use a qualified heating engineer.
The above information is so you are more aware of how and why you would need to top up your heating frequently. For more expert advice please call 952 .
Help! For about three months now Ive had to top my boiler up daily as its ben dropping to 0.4 bar. Interesting, the boiler only drops after a few hours after the heating has been on. I dont believe it drops when its not been on..
My boiler maintenance co have replaced the expansion vessel and prv to date but tell me it must be a leak in the pipes somewhere. I cant see any signs of leaks (nothing obvious after looking under the floor areas that I can reach and I dont see any signs from the ceilings..).
If I isolate the boiler for 24hrs should I let the heating try and come on as per the schedule or just leave it off?
any other ideas?
thanks.
Contact us to discuss your requirements of Industrial Steam Boiler. Our experienced sales team can help you identify the options that best suit your needs.
Previous: Maximize Efficiency with Vertical Plating Machines Today
Next: How drywall is made - material, manufacture, making, used ...
If you are interested in sending in a Guest Blogger Submission,welcome to write for us!
All Comments ( 0 )